Verification Example - RC Column
Eurocode Verification: NCM vs Nonlinear Analysis
Overview
Slender reinforced concrete columns require consideration of second-order effects — the additional moments arising from lateral deflections under axial load (P-δ effects). Eurocode 2 provides two approaches: simplified methods (NCM) that estimate these effects indirectly, and general methods that capture them directly through nonlinear analysis.
This example verifies Awatif's implementation against a published Eurocode reference example for a highly slender column (λ = 100), comparing:
Linear + NCM
First-order analysis with Nominal Curvature Method(EN 1992-1-1 §5.8.8)
Nonlinear
Geometrically nonlinear analysis with nominal stiffness(EN 1992-1-1 §5.8.7)
Problem Summary
Geometry
- Height: 6.20 m
- Section: 400 × 450 mm
Materials
- Concrete: C30/37
- Steel: S500
Loading
- NEd: 633 kN
- M0: 99.5 kNm
NCM Verification Details
Step-by-step comparison of Nominal Curvature Method calculations:
| Parameter | Symbol | Reference | Awatif (NCM) | Ratio | Awatif (Nonlinear) |
|---|---|---|---|---|---|
| First-order moment | M0 | 100.00 kNm | 99.50 kNm | 0.995 | — |
| Imperfection eccentricity | ei | 2.10 cm | 2.07 cm | 0.986 | 2.07 cm |
| Effective length | l0 | 13.02 m | 13.02 m | 1.000 | 6.2 m |
| Slenderness ratio | λ | 100.23 | 100.23 | 1.000 | — |
| Correction factor | Kr | 1.000 | 1.000 | 1.000 | — |
| Second-order eccentricity | e2 | 19.90 cm | 19.97 cm | 1.004 | — |
| Second-order moment | M2 | 126.00 kNm | 126.44 kNm | 1.003 | — |
| Design moment | MEd | 239.00 kNm | 239.02 kNm | 1.000 | 226.35 kNm |
| Steel area | As | 1620 mm² | 1580 mm² | 0.975 | 1471 mm² |
Steel area: Reference uses ω-method (graphical interpolation) leading to reading inaccuracies (1620 mm²). Awatif uses iterative calculation (1580 mm²). All other ratios within 1%
Verification Summary
All NCM calculation steps match the Eurocode reference within 1% tolerance. The step-by-step parameter comparison confirms correct implementation of slenderness checks, curvature calculations, and second-order moment amplification per EN 1992-1-1 §5.8.8.
The geometrically nonlinear analysis with nominal stiffness (EN 1992-1-1 §5.8.7) produces physically consistent results. The 5% reduction in design moment (226.35 kNm vs 239.02 kNm) reflects the method's direct equilibrium calculation versus NCM's conservative amplification approach. Steel area requirement reduced from 1580 mm² to 1471 mm².
This verification example demonstrates that Awatif correctly implements both Eurocode-approved methods for second-order effects. Users can select the appropriate method based on project requirements, with confidence in the implementation accuracy.